Air Handling Unit Calculation Download

Use it if you are looking for a fast loading small sized... Changing user policy was not easy to change from the... I own a furniture factory and have been using PaneCutter... Many programs starts automatically while you switch on... Helps to insert unicode characters in any application... Finally you can add awesome backgrounds to your facebook... No other burning software can write files to CD/DVD... The firewall does exactly what it claims - monitors which... Streaming audio files live online with your desired... The standard notepad never used to show the ASCII...Home / Download info / Flexit Calculation Select Air Handling Unit and get product data. Easy to find the best unit for each project. See dimensions drawing of the selected unit. Save drawing as DXE file Valid version is 2016.3.1 File 1: Flexit Calculation Program N.B. Always install file 1 first. File 2: Flexit MagiCad plugin 64 bit for AutoCad N.B. Always install file 1 first.

MagiCad - Autodesk AutoCad 64bit File 3: Flexit MagiCad 64 bit plugin Revit N.B. Always install file 1 first.MagiCad - Revit 64bit. A program for opening PDF files (e.g.Adobe Acrobat Reader) is required for printouts. Reader can be downloaded (Acrobat Reader)Flexit program runs with the following operating systems:Windows 7. Windows 98, Windows NT 4.x, Windows 2000, Windows ME, Windows XPCPU: 166MHz Pentium Memory: 64 MB Screen resolution: 800x600 (Super VGA) Used colors: 256 Registration (you will receive a mail when a new version of program can be downloaded): Please send mail to registrering@flexit.noSelection software, IV Produkt Designer Build your air handling unit in IV Produkt Designer G3 and you will receive a dimensionaland finished drawing complete with engineering data that includes SFPv values, temperatureefficiencies and sound data, etc.The program generates a three-dimensional model of the air handling unit, which can be importedinto AutoCAD, (DXF).

You can also make a lifecycle cost calculation (LCC) for a air handling unit.Fill in your contact information so you can download the latest version of IV Produkt selection program IV Produkt Designer G3, version 305.7.3.0. Find PDF by Order No ProUnit is a calculation program for dimensioning and selecting air handling units. ProUnit can be found in a web-based version. In the program you will receive the technical performance for Swegon's air handling units, GOLD. Swegon AB retains the right to upgrade the program and there to connected documentation without notice. ProUnit is developed and owned by Swegon AB and is protected by European copyright laws and international agreements. The program should be treated as all other documentation that are protected by copyright laws. All types of questions about the program are to be answered by Swegon AB. There are also plugins for CAD programs like AutoCAD and Revit and connections for MagiCAD. These can be downloaded under the "Downloads" tab.

There you can also find instructions for the different plugins. For ProUnit to work, some specific security settings must be made in your web browser. Read the instructions found under the Downloads tab how to make these settings in Internet Explorer.
Lab Pups For Sale Wa State AutoCAD connection guide (external link) Revit connection guide (external link) Internet Explorer Security Settings Guide how to set up your browser for ProUnit.
Super Single Tire And Wheel Weight Other manuals and instructions are available on the Plugins page (link below).
Fix Loose Bathroom Towel Rack CAD Plugins (external link)Dust Collection System Information Dust collection design can be complicated, here are a few simply steps to laying out an effective and efficient dust collection system.

We have simplified the dust collection system design process for smaller shops, it is important to know federal, state and localities have codes and regulations enforced by AHJ (Authorities Having Jurisdiction) governing sales, construction, installation and or use of dust collection systems. Air Handling Systems by Manufacturers Service Co., Inc. cannot guarantee compliance, and cannot be responsible for how the Product is installed or used. Before purchase and use of a Product, please review the Product application, national & local codes, regulations, and be sure that the Product, dust collection design, installation, and use will be in compliance. Download our Air Handling Design Guide. We can also offer you Tips on Installing your Air Handling System. Download our Take off list for Quotes to ease the process of quoting. Simply fill in quantities needed and fax it over to us at 800-438-7135. Download our CFM Requirements and Proper Branch Diameter Sizes guide to view proper CFM requirements and branch diameter sizes.

2. Follow these written directions: Before you start designing your Air Handling System you need a floor plan of your shop area including the following: Location of dust producing machines: indicate size & location of dust pick ups on each machine. Desired location of dust collector unit. Floor to joist measurement. Any obstructions that would interfere with the run of the duct. 3. Familiarize yourself with these terms: CFM – Air Volume in cubic feet per minute. FPM – Velocity of Air in feet per minute. SP – Static Pressure. This is expressed in inches water gauge. It is resistance to air at rest in a duct, and is also commonly called “resistance”, “friction”, “friction loss”, or “pressure loss.” VP – Velocity Pressure: expressed in inches water gauge. It is kinetic pressure in the direction of flow necessary to cause air at rest to flow at a given velocity. It is best to do the following calculations before you purchase your Dust Collector or the necessary ductwork.

Proper Size of Duct Use the chart below to determine the velocity of your system. Determine the size of each branch There are several ways to determine the diameter of the branches. If the machine has a factory installed collar, the manufacturer has determined that the machine needs that size branch under normal circumstances. If the machine has a metric diameter outlet, convert it into inches, and round off to the nearest inch. When writing up your parts list you may need to order a custom reducer. If the outlet is rectangular you need to determine the equivalent round diameter. When you write up your list use a transition. If the branch is smaller than 3″ diameter plan using a reducer near the machinery to increase the branch to 3″. Figure the CFM for 3 “(195 CFM). Determine CFM requirements for each branch. Under the proper velocity note the CFM of each branch. If working with wood dust, use 4000 FPM in branches ( see above – A) Duct Velocity ).

Determine Diameter of Main Duct Determine which machines are your primary machines. A primary machine is the machine(s) that will operate at the same time under the worst conditions. (If you normally operate two machines, but once a week need to operate a third machine at the same time, then you must size your system for all three machines.) We generally highlight the primary machines on the drawing. Sizing the Main Trunk Line. When sizing the main truck line start with the primary machine farthest from the duct collector. Run that size duct until the next primary branch enters the main. Increase the main size at that junction to accommodate theCFM total of the two primaries. You will follow this practice all the way to the collector, sizing all primary junctions, to accommodate total CFM of all primaries at that point. Do not increase main duct size when a branch other than a primary enters. Your total CFM requirement is the total of all primary branches. When not using a primary machine you will close blastgate and divert suction to a secondary machine.

You have 3 primary machines. You have already assigned the branch diameter and CFM requirements. A 4″ branch will be run from the Table Saw until it joins with the 4″ branch from the Lathe. At this point your main starts and you need to increase the pipe to handle the combined CFM (350+350 = 700). Using the CFM Chart 1 look up 700 CFM under the appropriate velocity (3500 FPM in the main for wood dust), then look at the corresponding diameter (6″). Run 6″ pipe in the main from the Lathe until the branch of the Radial Saw joins the main. Here again you need to increase your main to handle the total CFM (700+550=1250 CFM). Using the chart again you will see that 1250 CFM is slightly more than volume for 8″ diameter. Drop back to 8″ diameter so as not to go below transport velocity. Run the 8″ duct in your main from the Radial Saw to your Dust Collector. If you are installing an indoor re-circulating dust collector you need not calculate any more duct diameters.

If you are attaching ductwork to the exhaust side of your duct collector it is accepted practice to use a duct diameter two diameters larger on the exhaust side than on the inlet side, thus minimizing exhaust and duct resistance. CFM requirements for diameter at specified velocity Static Pressure based on 100′ of Pipe Elbow to Straight Pipe Conversion Figure System Resistance (SP) The total static pressure is several factors added together. They are entry loss, dirty filter loss, static pressure of the worst branch duct, static pressure of the main duct, and static pressure of the return duct. There are more complicated ways to figure the entry loss of your system, but we find it usually equals a loss of 1″ water gauge. (Use 1″ as a constant.) If your system has filters, add in 2″ loss. (If you do not have filters add zero). The Worst Branch, is the branch with the greatest resistance. The branch with the greatest resistance is usually a smaller diameter with the most lineal footage of pipe elbows.

Static pressure of worst branch and main duct can be calculated by using the following Chart 2. Chart 2 is based on 100 feet of pipe; therefore, you have to convert all elbows to an equivalent of pipe.To convert 90° and 45° elbows to equivalent feet of pipe use our Elbow to Straight Pipe Conversion chart. When figuring the feet of pipe count lateral type branches as 45° elbows. Flexhose has a lot of resistance depending on the amount of bends included in the installation. For this reason we suggest you keep hose to a minimum. Multiply your length of flexhose on your worst branch by 3 for equivalent length of straight pipe. Example: Determine Static Pressure of Worst Branch Static Pressure (Inches of Water Gauge) in Worst Branch (4″ Table Saw) Description – 4″ Diameter Equivalent to Straight Pipe 2 – 90° elbows 2 – 45° elbows Total equivalent straight pipe after conversions Example: Static Pressure in MAIN DUCT 6″ and 8″ The static pressure of the Main Duct is done the same way, except you figure it out for each diameter in the Main, starting farthest away and working toward the collector.

Description – 6″ Diameter 700 CFM in 6″ diameter = 3.5″ S.P. per 100′ 700 CFM in 6″ diameter = .70″ S.P. per 20′ Description – 8″ Diameter 1,250 CFM in 8″ diameter = 2.4″ S.P. per 100′ 1,250 CFM in 8″ diameter = 1.3″ S.P. per 55′ (8″ Diameter runs to self contained Dust Collector) Total Static Pressure: 1″ + 2″ + 3.71″ + .70″ + 1.3″ = 8.71″ S.P. Inches Water Gauge. System Requirement: 1,250 CFM at 8.71″ SPWG Wrapping Up and Ordering Parts If clean air return duct is required, duct resistance should also be calculated. Now you have all the information you need to make an educated decision in purchasing your dust collector. You have determined the Velocity, CFM, Static Pressure and the size of the ductwork. To develop your list of materials required, go through the system; this time starting at the dust collector and list each part you will need. Don’t forget the assembly equipment such as: pop rivets, hangers, strapping, caulking, and couplings.